190 | Bug Report | Low | dvg_snmp better restart support | Assigned | 17.09.2014 | | |
|
Task Description
restart of a host doesn’t always work well (eg. snmp is polling, execute or modules aren’t) the up/down isn’t always detected correct (the hosts stays down even it is up)
|
|
188 | Feature Request | Medium | inode graph with the disks graphs | Assigned | 29.06.2014 | | |
|
Task Description
A state of used inodes could be nice ...
|
|
185 | Feature Request | Low | Host-table: add Serial number | Assigned | 25.01.2014 | 0.9.5 | |
|
Task Description
Add a field to the host table to store the serial number of the host.
|
|
177 | Feature Request | Low | create inventory per customer | New | 26.01.2013 | | |
|
Task Description
Create a inventory for each customer id / Location, …
|
|
176 | Feature Request | Low | More Hardware types | Assigned | 26.01.2013 | 0.9.5 | |
|
Task Description
Add a mask to add more hardware types
This should be a option on the hardware page
|
|
175 | Feature Request | Low | add search for local loops, provider, technologie | New | 10.02.2013 | 1.0.0 | |
|
Task Description
in the global search form you cannot search for locallops, provider nor technologie
|
|
171 | Bug Report | Low | Remark | Assigned | 02.01.2013 | 0.9.5 | |
|
Task Description
New Config Optons
<REMARK enabled="1">
<show_remark_to_guest>[yes|no]</show_remark_to_guest>
<edit_remark_by_guest>[yes|no]</edit_remark_by_guest>
<show_remark_to_customer>[yes|no]</show_remark_to_customer>
<edit_remark_by_customer>[yes|no]</edit_remark_by_customer>
</REMARK>
if the show_remark_to… entry is disabled the edit_remark_by… entriy is meaningless
|
|
156 | Bug Report | Low | Polling Daemon | Assigned | 28.12.2011 | | |
|
Task Description
the daemon loses the target if the target isn’t reachable a longer time.
|
|
152 | Feature Request | Low | Ping probe should honor IPv4 and/or IPv6 Protokoll | Requires testing | 13.06.2011 | 0.9.5 | |
|
Task Description
The ping probe should check if a host is reachable via IPv4 or IPv6. The result for the different Protokolls should be recorded in the graphs.
|
|
151 | Feature Request | Low | Uptime: Detail der UP/DOWN Messages | Assigned | 04.12.2012 | | |
|
Task Description
Bei den Uptime meldungen sollte eine Link existieren, der die genauen UP/Down Zeiten pro Jahr und/oder Monat angibt.
In der dvg_host_status Tabelle sollte die changed Zeitstempel besser (für die Performance) als unix timestamp abgelegt werden.
|
|
134 | Feature Request | Low | Login with (Cacaert) User Certificate | New | 05.06.2011 | | |
|
Task Description
Instead of the username and passwort an user-certificate from cacert.org or any other CA or an OpenID account should be allowed to use for login.
|
|
103 | Feature Request | Low | neue Tabelle dvg_link_type -> dvg_link | Assigned | 03.04.2009 | 0.9.5 | |
|
Task Description
Database Tabelle dvg_link_type: Die Werte (type_id is null) aus dieser Tabelle sollen anstelle der fixen enum Werte in Tabelle dvg_link verwendet werden.
|
|
95 | Feature Request | Low | add peak graphs | New | 31.10.2006 | 0.9.5 | |
|
Task Description
vmstat: add peak graphs for IO-, IRQ/Context-,Swap Graph
|
|
91 | Feature Request | Low | Scrollen | Assigned | 03.04.2009 | 0.9.5 | |
|
Task Description
On screens with more than X results it should be possible to scroll through the data.
Following variables could be used globaly in the URLs:
pos=n startpostition in the data; (n>=0)
show=n how many rows should be shown on the screen
pos and show should be configurable
There are some pages who could use this feature: backbone.php if the page get too long, Hosts with more then n devices, ...
|
|
79 | Feature Request | Medium | Creating devices | Assigned | 04.12.2012 | 1.0.0 | |
|
Task Description
Mass create von Devices.
Mehrere - gleiche - Devices mit denselben Parametern hinzufügen. Der Name der Devices wird nummeriert. z.b. “Ethernet 101/%d” soll entsprechend strfrmt ausgewertet werden und mit der laufenden Nummer versehen werden. Die Startnummer, Anzahl und Schrittgrösse sollen definiert werden können.
|
|
76 | Feature Request | Low | title-tag | Assigned | 03.04.2009 | 1.0.0 | |
|
Task Description
Alle Links sollten einen Title-tag, der die Funktion des Linkes beschreibt enthalten.
|
|
70 | Feature Request | High | Polling Daemon | Requires testing | 20.07.2011 | 0.9.5 | |
|
Task Description
siehe: http://www.dvgtool.org/DOCU/doku.php?id=design:snmpdaemon
|
|
69 | Feature Request | Low | IPv6 Verwaltung | Assigned | 15.01.2012 | 0.9.6 | |
|
Task Description
normaly the DVG pages are generated and send to th browser. for some pages it would be great if the relaod from time to time (mostly the pages showing rrd-graphs)
|
|
54 | Feature Request | Low | Service Checks zu Hosts | New | 16.12.2005 | | |
|
Task Description
Jeder Host sollte mehrere Services besitzen, die dann getestet werden, analog Nagios/devpatrol.
Sie Services/Checks koennen mehrere Stati haben: UP, WARN, CRIT, DOWN, MAINTENANCE, die farblich unterschiedlich dargestellt werden.
Dazu sollte es eine Uebersichtsseite geben die alle Hosts mit einem bestimmten Status anzeigt.
Die Alarmierung sollte dann von einem weiteren Daemon uebernommen werden, oder so, das kann man noch diskutieren.
|
|
48 | Feature Request | Low | dvg_hostdesc.pl | Assigned | 04.12.2012 | | |
|
Task Description
dvg_hostdesc.pl:
erstellt im Moment ein Inventar der Cisco-Geräte in dem Cisco spezifische SNMP-Parameter abgefragt werden.
Dies sollte modularisiert werden, so dass auch Geräte von anderen Herstellern erfasst werden können.
Andererseit soll die Cisco-Abfragen detaillierter gestaltet werden, so dass am Schluss auch die eingebauten Interfacekarten aufgelistet werden.
|
|
3 | Feature Request | Low | Audit Function | Assigned | 04.12.2012 | 1.0.0 | |
|
Task Description
Die Idee ist, dass jede Ãnderung zusätzlich in einer Audit-Datei / -Tabelle protokolliert wird. (wer,was,wann)
z.B.: add_host #22, ueli, 2003-12-28 16:48:22
|